WELCOME TO OUR BLOG

We're sharing knowledge in the areas which fascinate us the most
click

How to Choose Bitzer Refrigeration Oil?

Oleh Qishanr Lubricants September 28th, 2025 pandangan 153

1. Start with Compressor Type: The Foundation of Oil Selection​

Reciprocating Compressors​

For classic reciprocating models like the 6F-50.2 and 4FC-3.2:​
  • If using R22 refrigerant, the only suitable option is B5.2 mineral oil. Pay strict attention to oil fill volume:​

  • 6F-50.2 requires 4.75L​
  • 4FC-3.2 requires only 1.8L​
Underfilling causes insufficient lubrication; overfilling increases compressor load.​
  • If using eco-friendly refrigerants (e.g., R134A, R404A), switch to synthetic POE oil:​

  • Choose BSE32 for daily condensing temperatures below 55°C (e.g., supermarket refrigerators). Its water content is <50ppm, preventing ice blockage when mixed with refrigerants.​
  • Choose BSE55 if condensing temperatures often exceed 55°C (e.g., industrial refrigeration in high-temperature environments). It has stronger anti-decomposition performance, reducing oil loss by 30%.
  • BSE55:​

2. Screw Compressors: Larger Variations by Operating Conditions​

Screw compressors demand more precise oil matching based on working scenarios:​

​
Scenario​
Refrigerant​
Recommended Oil​
Key Advantages & Compatible Models​
Normal-temperature heat pumps (e.g., hotel hot water systems)​
R22​
B320SH (complex ester oil)​
Maintains stable viscosity at 60°C high condensing temperature; fits CSH7571-90, CSW8571-120.​
Normal-temperature heat pumps​
R134A​
BSE170​
Excellent miscibility with refrigerants; reduces oil foaming and oil pressure fluctuations.​
Low-temperature freezing (e.g., -30°C cold storage)​
R22​
B100 / B150SH​
B100 for -25°C+; B150SH remains fluid at -45°C; fits HSK7471-100, HSN8571-140.​
Low-temperature freezing​
R404A​
BSE170​
Total acid number <0.02mgKOH/g; slows pipe corrosion and extends equipment life.​

BSE170:

​

3. 4-Step Practical Checklist​

  1. Check compressor model: "F" = reciprocating; "CSH/HSK" = screw (found on the compressor nameplate).​

  1. Confirm refrigerant type: Listed on the equipment nameplate—never mix oils for R22 and eco-friendly refrigerants.​
  1. Match oil to operating conditions: Refer to Bitzer’s official "Condition-Oil Compatibility Chart" (available on Bitzer’s website) for condensing/evaporating temperatures.​
  1. Verify oil fill volume: Underfilling triggers motor protection; overfilling may cause excessive discharge temperature.

Selection and Application Guidelines for Emkarate RL Refrigeration Lubricants
Sebelumnya
Selection and Application Guidelines for Emkarate RL Refrigeration Lubricants
Baca Lagi
Hitachi Refrigeration Oil: 3-Pronged Protection for Your Unit
Seterusnya
Hitachi Refrigeration Oil: 3-Pronged Protection for Your Unit
Baca Lagi
Leave a message
Name *
E-mail *
Message *
Phone
Country
CONTACT US *
Kod Pengesahan